ION 6200




The ION6200 meter offers outstanding quality, versatility, and functionality in a lowcost, ultra-compact unit. The meter is simple to use and offers a big, bright LED display for superior readability in poor lighting conditions. Complete with four-quadrant power, demand, energy, power factor, and frequency measurements, this versatile unit is easy to wire and mount. It offers an excellent upgrade path that lets you start with a low-cost base model and add enhanced
functionality over the long term. The ION6200 meter lets you upgrade functionality in the field by activating the base
unit. Rather than carry a large inventory of pre-configured meters, genset and electrical equipment manufacturers, panel shops, EMS manufacturers and energy service providers can each adapt meter functionality to specific applications as required.

Applications
Class 0.5S metering and sub-metering.
Replace multiple analog meters.
Basic metering.
Cost allocation.
Substation monitoring.

Standard Measurements
Voltage, Current, Energy, (kWh) Imported/Exported, Power, (kW), Peak power demand (kW), Current Demand, Peak Current Demand, Neutral, Frequency, Power factor, Power, (kW) Per Phase, Power factor, Reactive Energy, (kVARh) Import/ Export, Apparent Energy, Reactive Power, Apparent Power, Peak Demand, THD Voltage & Current, Energy, (kWh) Import/Export

Accuracy certification
This meter offers IEC 60687 Class 0.5S accuracy for use as a tariff meter.

Accuracy
The class of accuracy of the Energy Meter is 0.5 Class.

Pulse Outputs
Optional kWh, kVARh and/or kVAh pulsing via two Form A outputs

Applications:
Panel Metering, AMR, APC, Substation Automation, Industrial metering etc.


Please click here for downlaod the datasheet

Class 1.0 Energy Meter




RM 705 L3 is a state-of-the-art Digital Multifunction Meter of class 1.0 accuracy and especially designed for panel meter application. The meter meets the IS standards.
The meter is equipped with RS485 communication port for implementation of Energy Management Systems application.

Measurement Parameter

• True RMS measurement
• Voltage & Current
• KW, kVA & kVAr
• Power Factor
• Frequency
• Energy: Active & Reactive

Voltage Inputs

• 110 to 500 VAC
• Supports 3 Phase 3 wire, 3 Phase 4 wire
Connection

Power Supply

110 V / 230 V AC

Current Inputs

• 1/ 5 Amp
• Burden on CT < 0.2 VA

Data Loging
The RM Series provides data logging facility with Time Stamping property.
The meter data can be get through RS 485 communicatio port.

Software Integration

The meters can be integrated with an Energy Mangement or SCADA system to provide remote display of all measured parameters and meters configurations. The meter communicates on MODBUS RTU protocol via RS 485 port.

Applications:

Panel Metering, AMR, APC, Substation Automation, Industrial metering etc.

Counter type KWh Meter



RM 506 K is a low cost, very much affordable and simple in use a static energy meter. It has pulse output, which can be connected to any data logger as a part of energy accounting system.

Advantages

• Provide a basic foundation for a successful energy management plan.
• Record and track the progress of energy saving strategies.
• Provide a basis for setting realistic energy savings goal.
• Indicate possible areas for improving O&M.
• Specific Energy Consumption Analysis

Voltage Inputs
• 40 to 440 VAC
• Supports 3 Phase 3 wire, 3 Phase 4 wire Connection

Current Inputs

• 1/ 5 Amp

Out Put

Pulse Out Put for Energy Counting and calibration.

Applications:

Panel Metering, Industrial metering etc.

Automatic Meter Reading System



CMS Solution for Automatic Meter Reading System
CMS Automatic meter reading or AMR Systems, is the technology of automatically collecting data from energy/ water/ gas meters and transferring that data to a central database through various communication channels for billing, analyzing and postmarking the energy uses.
The data from the IED (Intelligent Electronic Device) may come to the central server by various communication media like handheld, Serial Communication (RS 485, RS 232, RS 422), GSM/ GPRS, LPR (Low Power Radio), PLC (Power Line Communication), Zigbee etc.

Critical Benefits from AMR System

• Ability to detect tamper events and outage occurrences.
• Remotely Connect/ Dis-connect power supply through meter.
• Calculate transformer loading and sizing from interval data
• 15 minute interval data gives accurate load information for supply scheduling, switching operations, planning etc
• Monitor voltage at each premise to know conditions when to operate capacitor switches or regulators
• Consistent and node wise data for improved accuracy
• Automatic bill generation and consumer account analysis



Saturday, February 21, 2009

Load Analyzer

CMS Introduces Load Analyzer for standalone Motor, Pump, Boiler, Fan etc.

Catalog: RM 705 L4